Cooling Tower Maintenance Audit Checklist

A comprehensive checklist for auditing cooling tower maintenance practices, ensuring optimal performance, safety, and compliance with industry standards.

Get Template

About This Checklist

The Cooling Tower Maintenance Audit Checklist is an essential tool for ensuring the efficient operation and longevity of cooling tower systems. This comprehensive checklist addresses critical maintenance tasks, safety protocols, and performance evaluations, helping facility managers and maintenance teams identify potential issues before they escalate. By implementing regular audits using this checklist, organizations can minimize downtime, reduce energy consumption, and maintain compliance with industry standards. The checklist covers key areas such as water treatment, mechanical components, and environmental impact, providing a structured approach to cooling tower maintenance that ultimately leads to improved system reliability and cost savings.

Learn more

Industry

Facility Management

Standard

ASHRAE Standard 188 - Legionellosis Risk Management

Workspaces

Data Centers
Hospitals
Commercial Buildings
Industrial Facilities

Occupations

Facility Manager
HVAC Technician
Maintenance Engineer
Water Treatment Specialist
Environmental Health and Safety Officer

1
Are there documented procedures in place for Legionella prevention in the cooling tower?

Please indicate if procedures exist.

This ensures compliance with health standards and reduces the risk of Legionnaire's disease.
2
Is the water treatment for the cooling tower compliant with ASHRAE Standard 188?

Select compliance status.

Compliance ensures effective water treatment and minimizes risks associated with waterborne pathogens.
3
What is the current water temperature in the cooling tower?

Enter current temperature in degrees Celsius.

Monitoring water temperature is essential for efficient operation and energy management.
Min10
Target30
Max50
4
Provide details of the preventive maintenance schedule for the cooling tower.

Please describe the preventive maintenance schedule.

A documented schedule is necessary to ensure regular maintenance and operational reliability.
5
What is the energy efficiency rating of the cooling tower?

Select the energy efficiency rating.

Energy efficiency ratings help in assessing the performance and potential cost savings of the equipment.

6
Are emergency shutdown procedures clearly documented and accessible?

Indicate if procedures are documented and accessible.

Having documented procedures ensures safety during emergencies and compliance with industry regulations.
7
Are maintenance records for the cooling tower readily available for review?

Select the availability status of maintenance records.

Accessible maintenance records are crucial for audits and ensuring compliance with maintenance protocols.
8
What is the current pH level of the water in the cooling tower?

Enter the current pH level.

Monitoring pH levels is essential for effective water treatment and preventing equipment corrosion.
Min6.5
Target7.5
Max8.5
9
Describe the chemicals used for water treatment in the cooling tower.

Provide details about the water treatment chemicals.

Knowing the chemicals used is important for compliance with environmental regulations and safety.
10
When was the last inspection of the cooling tower conducted?

Enter the date of the last inspection.

Regular inspections are crucial for identifying issues early and ensuring compliance with safety standards.

11
Is safety equipment (e.g., personal protective equipment) available for staff working near the cooling tower?

Indicate if safety equipment is available.

Availability of safety equipment is essential to protect personnel and comply with safety regulations.
12
Have all personnel received training on cooling tower safety procedures?

Select the training status.

Training ensures that personnel are aware of safety protocols and reduces the risk of accidents.
13
What is the current noise level produced by the cooling tower?

Enter the noise level in decibels (dB).

Monitoring noise levels is important for environmental compliance and ensuring safe working conditions.
Min50
Target85
Max100
14
Provide details of any incidents or near misses related to the cooling tower in the past year.

Please describe any incidents or near misses.

Documenting incidents helps in identifying hazards and improving safety practices.
15
When is the next scheduled safety audit for the cooling tower?

Enter the date of the next scheduled safety audit.

Scheduling regular audits is essential for maintaining safety compliance and identifying potential hazards.

16
Is the operational status of the cooling tower monitored continuously?

Indicate if operational status is monitored.

Continuous monitoring helps in identifying performance issues and ensuring efficient operation.
17
What is the performance rating of the cooling tower based on recent evaluations?

Select the performance rating.

Performance ratings provide insights into the efficiency and reliability of the cooling tower system.
18
What is the current energy consumption of the cooling tower in kilowatts?

Enter the energy consumption in kilowatts.

Monitoring energy consumption is essential for identifying efficiency improvements and cost savings.
Min50
Target150
Max300
19
Describe any modifications made to the cooling tower in the past year.

Please provide details of any modifications.

Documenting modifications helps in understanding changes that may affect performance and compliance.
20
When was the last performance evaluation conducted on the cooling tower?

Enter the date of the last performance evaluation.

Regular performance evaluations are critical for maintaining system efficiency and reliability.

21
Is the usage of chemicals in the cooling tower compliant with environmental regulations?

Indicate if chemical usage is compliant.

Ensuring compliance with environmental regulations minimizes negative impacts on surrounding ecosystems.
22
Is the water discharge from the cooling tower compliant with local environmental standards?

Select the compliance status of water discharge.

Compliance with discharge standards is essential to prevent water pollution and protect local water sources.
23
What is the total water usage of the cooling tower system in liters per day?

Enter the total water usage in liters.

Tracking water usage helps in assessing the environmental impact and identifying conservation opportunities.
Min500
Target1000
Max5000
24
Describe any measures taken to mitigate the environmental impact of the cooling tower.

Please provide details of mitigation measures.

Documenting mitigation measures is essential for demonstrating commitment to environmental stewardship.
25
When was the last environmental impact assessment conducted for the cooling tower?

Enter the date of the last environmental assessment.

Regular assessments are vital for identifying potential environmental risks and ensuring compliance.

FAQs

Cooling tower maintenance audits should be conducted at least quarterly, with more frequent inspections during peak cooling seasons or in harsh environments.

Key areas include water quality testing, mechanical component inspection, fan and motor performance, fill media condition, and overall system cleanliness.

Cooling tower maintenance audits should be performed by qualified facility engineers, HVAC technicians, or specialized cooling tower maintenance professionals.

By identifying and addressing issues such as scale buildup, clogged nozzles, or inefficient fan operation, the audit helps maintain optimal heat transfer and reduces energy consumption.

Safety considerations include proper lockout/tagout procedures, fall protection measures, personal protective equipment usage, and awareness of potential biological hazards such as Legionella.

Benefits

Ensures compliance with maintenance standards and regulations

Reduces the risk of equipment failure and unplanned downtime

Improves energy efficiency and reduces operational costs

Extends the lifespan of cooling tower systems

Enhances water conservation efforts and environmental sustainability