Data Center HVAC and Environmental Control Systems Audit Checklist

A comprehensive checklist for auditing HVAC and environmental control systems in data centers, focusing on temperature management, humidity control, air quality maintenance, and energy-efficient cooling strategies to ensure optimal operational conditions and energy efficiency.

Data Center HVAC and Environmental Control Systems Audit Checklist

by: audit-now
4.5

Get Template

About This Checklist

The Data Center HVAC and Environmental Control Systems Audit Checklist is a vital tool for ensuring optimal operational conditions and energy efficiency in modern data centers. This comprehensive checklist addresses key aspects of heating, ventilation, air conditioning, and environmental management, including temperature control, humidity regulation, air quality maintenance, and energy-efficient cooling strategies. By conducting regular audits of HVAC and environmental control systems, organizations can maintain ideal conditions for IT equipment, optimize energy consumption, extend hardware lifespan, and ensure compliance with environmental standards. This checklist is essential for facility managers, HVAC engineers, and data center operators committed to maintaining a stable, efficient, and environmentally controlled data center ecosystem.

Learn more

Industry

Information Technology

Standard

ASHRAE Data Center Thermal Guidelines

Workspaces

Data Centers

Occupations

HVAC Engineer
Data Center Facilities Manager
Environmental Systems Specialist
Energy Efficiency Consultant
Data Center Operations Manager
1
What is the efficiency rating of the chillers used in the data center?
​
Min: 4
Target: Above 5.0
Max: 10
2
When was the last maintenance performed on the HVAC system?
​
3
Is free cooling being utilized in the data center?
4
Please provide any comments regarding compliance with thermal guidelines.
​
5
Are emergency cooling systems in place and operational?
6
What is the current temperature set point for the data center?
​
Min: 15
Target: 20-24
Max: 30
7
What is the current humidity set point for the data center?
​
Min: 30
Target: 45-55
Max: 70
8
What type of cooling system is currently implemented?
9
Is there a regular monitoring process for environmental conditions in the data center?
10
Please provide any additional comments regarding environmental control measures in place.
​
11
What is the current PUE (Power Usage Effectiveness) of the data center?
​
Min: 1
Target: 1.2-1.5
Max: 2
12
Are energy monitoring tools utilized in the data center?
13
Is the data center utilizing any renewable energy sources?
14
Please provide any additional comments regarding energy efficiency initiatives in the data center.
​
15
What is the current energy consumption of the HVAC system?
​
Min: 0
Target: Below 30%
Max: 100
16
What is the total cooling capacity of the HVAC system in kW?
​
Min: 50
Target: 100-500
Max: 600
17
Are variable speed drives installed on the cooling units?
18
What cooling distribution method is employed in the data center?
19
Please provide any additional comments regarding the cooling efficiency of the data center.
​
20
What is the current return air temperature from the data center?
​
Min: 15
Target: 20-25
Max: 30
21
Auditor Name
​
22
Site/Location
​
23
Date
​

FAQs

Data center HVAC and environmental control system audits should be conducted quarterly, with continuous monitoring of temperature, humidity, and air quality metrics, and monthly reviews of energy consumption patterns.

Key components include assessing temperature and humidity control systems, evaluating air flow management strategies, reviewing air filtration and quality maintenance measures, examining cooling efficiency metrics, and analyzing the implementation of energy-saving cooling technologies.

According to ASHRAE guidelines, the recommended temperature range for data centers is 18-27°C (64.4-80.6°F), with a humidity range of 40-60% relative humidity. However, modern equipment often allows for wider ranges, potentially enabling more energy-efficient operations.

Data centers can implement energy-efficient cooling strategies through techniques such as hot/cold aisle containment, use of free cooling or economizers, implementing variable speed fans and pumps, utilizing liquid cooling for high-density racks, and optimizing air flow management.

Air quality management is crucial for preventing equipment damage from particulates, corrosive gases, or other contaminants. It involves proper air filtration, regular cleaning practices, monitoring of gaseous and particulate levels, and maintaining positive air pressure in the data center environment.

Benefits of Data Center HVAC and Environmental Control Systems Audit Checklist

Ensures optimal operating conditions for IT equipment

Improves energy efficiency and reduces operational costs

Extends the lifespan of hardware through proper environmental control

Enhances compliance with environmental and energy efficiency standards

Supports green data center initiatives and sustainability goals